Eicon Networks C20 Manuale delle Istruzioni Pagina 263

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 262
INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
Replacing Other Components
Page 7-33Power Supply Replacement
7
Power Supply Replacement
The 110/220-VAC power supply is located in the upper left corner of the MAP/5P
as shown in Figure 7-14
.
Figure 7-14. MAP/5P Internal Layout
Power Supply Removal
To remove the power supply, you must:
Remove the Lucent INTUITY system from service.
Access the power supply.
Extract the power supply.
1. Bay 6 - Hard Disk Drive 0
2. Bay 7 - Empty
3. Power supply
4. Motherboard
5. Riser card
6. Bay 1 - Cartridge tape drive
7. Bay 2 - Empty
8. Bay 3 - Empty
9. Bay 4 - Diskette drive
10. Bay 5 - Hard Disk Drive 1 (if used)
Vedere la pagina 262
1 2 ... 258 259 260 261 262 263 264 265 266 267 268 ... 409 410

Commenti su questo manuale

Nessun commento