Analyzing Data: ECMODULE TRACE
The ECMODULE TRACE function can be an essential tool for the data
communications expert. In most cases, you will use ECMODULE TRACE
under the guidance of an Eicon Networks representative.
The following command shows trace data on an X.25 connection:
ECMODULE TRACE X25 /T 256
X.25 Loadable Module Trace
Port number: 01 Port name: P1
X.25 Trace
Size = 2048 Length = 256 Block = 18 Mask = FF
BLK -HH:MM:SS:MSEC
1 -00:14:27.000 TX CALL REQ <10 04 0B> Data = 19
0A 55 40 03 46 22 00 CB 01 00 00 F0 F1 F3 F1 F9 ³[email protected]"..........³
F5 40 40 ³.@@ ³
2 -00:14:27.000 RX CLEAR IND <10 04 13> Data = 2
00 C5 ³.. ³
3 -00:14:27.000 TX CLEAR CNF <10 04 17> Data = 0
4 -00:14:27.020 TX CALL REQ <10 04 0B> Data = 19
0A 55 40 03 46 22 00 CB 01 00 00 F0 F1 F3 F1 F9 ³[email protected]"..........³
F5 40 40 ³.@@ ³
5 -00:14:27.020 RX CLEAR IND <10 04 13> Data = 2
00 C5 ³.. ³
6 -00:14:27.020 TX CLEAR CNF <10 04 17> Data = 0
7 -00:14:27.040 TX CALL REQ <10 04 0B> Data = 19
0A 55 40 03 46 22 00 CB 01 00 00 F0 F1 F3 F1 F9 ³[email protected]"..........³
F5 40 40 ³.@@ ³
8 -00:14:27.040 RX CLEAR IND <10 04 13> Data = 2
00 C5 ³.. ³
9 -00:14:27.040 TX CLEAR CNF <10 04 17> Data = 0
10 -00:14:27.055 TX CALL REQ <10 04 0B> Data = 19
0A 55 40 03 46 22 00 CB 01 00 00 F0 F1 F3 F1 F9 ³[email protected]"..........³
F5 40 40 ³.@@ ³
11 -00:14:27.055 RX CLEAR IND <10 04 13> Data = 2
00 C5 ³.. ³
12 -00:14:27.055 TX CLEAR CNF <10 04 17> Data = 0
13 -00:14:28.000 TX CALL REQ <10 04 0B> Data = 19
0A 55 40 03 46 22 00 CB 01 00 00 F0 F1 F3 F1 F9 ³[email protected]"..........³
F5 40 40 ³.@@ ³
14 -00:14:28.001 RX CLEAR IND <10 04 13> Data = 2
00 C5 ³.. ³
15 -00:14:28.001 TX CLEAR CNF <10 04 17> Data = 0
16 -00:14:28.015 TX CALL REQ <10 04 0B> Data = 19
0A 55 40 03 46 22 00 CB 01 00 00 F0 F1 F3 F1 F9 ³[email protected]"..........³
F5 40 40 ³.@@ ³
17 -00:14:28.015 RX CLEAR IND <10 04 13> Data = 2
00 C5 ³.. ³
18 -00:14:28.016 TX CLEAR CNF <10 04 17> Data = 0
Command Completed Successfully.
Command
ECMODULE TRACE option [/Filter f][/REset][/Block b]
[/Size n][/Truncate n][/EBcdic] [/Outfile f] [/?]